Skip to content
Megawa Solar

Request a Quote

We'll get back to you within 24 hours.

Optional details

Need a detailed engineering quote with structural analysis?

Start RFQ Process
Solar Cable mounting accessories
Mounting Accessories

Solar Cable

Request a Quote

Quote for Solar Cable · Mounting Accessories

Optional details

Need a detailed engineering quote with structural analysis?

Start RFQ Process

Single-core DC cable for PV strings: tinned copper conductor, halogen-free XLPO insulation, rated 1.5 kV DC. Quoted and shipped with your mounting system.

EN 50618 / IEC 62930 · Tinned copper · Halogen-free XLPO · 1.5 kV DC
0Rated Voltage (DC)
−40 to +90 °CAmbient Temperature
0Standard Cross Sections
0Warranty

Request a Quote

Quote for Solar Cable · Mounting Accessories

Optional details

Need a detailed engineering quote with structural analysis?

Start RFQ Process
SEC.01

Overview

This solar cable carries direct current from the modules to the combiner box or inverter. It is a single-core cable with a fine-stranded tinned copper conductor. Both the insulation and the sheath are halogen-free cross-linked polyolefin (XLPO). It is rated 1.5 kV DC and works in ambient temperatures from −40 to +90 °C.

We supply two types. H1Z2Z2-K is made to EN 50618, the standard used across Europe. The IEC 62930 type follows the international standard used in most other markets. The construction is the same, so the choice comes down to which standard your project specification or local code asks for. Standard sizes are 4, 6 and 10 mm², in red and black.

The cable is quoted together with the mounting system and loaded in the same container, so the structure and the DC wiring reach site together. It comes as bulk cable, or as extension leads cut to your lengths with MC4-compatible connectors already fitted.

SEC.02

Key Advantages

Made to Stay Outdoors

Insulation and sheath are both cross-linked polyolefin. The cable resists UV and works from −40 to +90 °C.

Low Smoke, No Halogens

The halogen-free compound gives off little smoke and no halogen acid gas in a fire. Flame-tested to EN 60332-1-2.

Less Loss on Long Runs

Fine-stranded tinned copper keeps resistance low: 3.39 Ω/km at 6 mm². The stranding also makes the cable easy to bend and route.

Arrives With the Mounting

Quoted, packed and shipped with your mounting system. Extension leads come cut to length with connectors fitted.

SEC.03

Technical Specifications

Structural
Cable TypesH1Z2Z2-K (EN 50618) · 62930 IEC 131 (IEC 62930)
ConductorTinned copper, fine-stranded (class 5)
Insulation and SheathHalogen-free cross-linked polyolefin (XLPO)
Rated Voltage1.5 kV DC · 1.0/1.0 kV AC
Test Voltage6.5 kV AC for 5 minutes on the finished cable
Ambient Temperature−40 to +90 °C
Short-Circuit Temperature+200 °C for up to 5 seconds
System
Flame TestEN 60332-1-2
ColorsRed, black
Extension Leads — ConnectorsMC4-compatible, fitted on both ends or on one end
Extension Leads — Rating1000 V or 1500 V DC, 30 A
Extension Leads — Cable Sizes2.5, 4, 6 or 10 mm²
Extension Leads — LengthMade to the lengths in your order
Warranty5 years
H1Z2Z2-K (EN 50618) — Standard Sizes
Cross Sectionmm²Conductor Constructionn × mmConductor DiametermmInsulation ThicknessmmSheath ThicknessmmOuter DiametermmDC ResistanceΩ/kmCurrent RatingA
456 × 0.2852.40.70.85.55.0944
684 × 0.2853.00.70.86.13.3957
1080 × 0.394.00.70.87.11.9579
DC resistance is the maximum value at 20 °C. Current rating at 60 °C ambient, for two loaded cables side by side on a surface. Insulation and sheath thicknesses are average values, not less than shown. Sizes from 1.5 to 35 mm² are available on request. Values follow the latest specification.
62930 IEC 131 (IEC 62930) — Standard Sizes
Cross Sectionmm²Conductor Constructionn × mmConductor DiametermmInsulation ThicknessmmSheath ThicknessmmOuter DiametermmDC ResistanceΩ/kmCurrent RatingA
456 × 0.2852.40.70.85.55.0945
684 × 0.2853.00.70.86.13.3958
1080 × 0.394.00.70.87.11.9580
DC resistance is the maximum value at 20 °C. Current rating at 60 °C ambient. Insulation and sheath thicknesses are average values, not less than shown. Sizes from 1.5 to 35 mm² are available on request. Values follow the latest specification.
SEC.04

Frequently Asked Questions

Should I use 4 mm² or 6 mm² cable?

It depends on string current and run length. A thicker cable has less resistance, so it loses less voltage. For example, on a 50 m run (100 m of cable out and back) at 13 A, 4 mm² drops about 6.6 V and 6 mm² about 4.4 V. Use 4 mm² for short runs and 6 mm² or 10 mm² for long ones. Send us your string layout and we will size it with the quote.

What is the difference between H1Z2Z2-K and IEC 62930 cable?

They are made to two standards. H1Z2Z2-K follows EN 50618, used in Europe. IEC 62930 is the international standard. Both are rated 1.5 kV DC and built the same way here. Older PV1-F cable is rated 1.0 kV DC, so it does not suit 1500 V systems.

Can the extension leads plug into the connectors on my modules?

The leads have MC4-compatible connectors. Installation standards ask that a plug and socket in one connection come from the same manufacturer and type. Tell us which connector your modules use, and check the pairing against your local code before ordering.

How long can the extension leads be?

They are made to the lengths in your order, with connectors on both ends or on one end. Leads are available in 2.5, 4, 6 and 10 mm² cable.

How do I order cable with a mounting system?

Add it to your quote request. Give us the system size and string layout, or the metres you need in each cross section and color. We quote the cable with the mounting system and ship them together. The cable carries a 5-year warranty and is designed for a 25-year service life.

Request a Quote

Itemized BOM, unit pricing and lead time — engineering reply within 24 hours.

RFQ · Solar Cable

Request a Quote

Quote for Solar Cable · Mounting Accessories

Optional details

Need a detailed engineering quote with structural analysis?

Start RFQ Process
Start Detailed RFQ →
Quick quote: 30 seconds. Detailed RFQ: ~3 minutes, prefilled with this product.Or reach us via the Contact page
Full RFQ

Request a Quote

Quote for Solar Cable · Mounting Accessories

Optional details

Need a detailed engineering quote with structural analysis?

Start RFQ Process